Ideal Logic: F2, flame loss
Asked: “Ideal Logic Combi F2”The boiler lights briefly, then loses the flame.
- Gas pressure below 18 mbar at the boiler inlet
- Detection electrode faulty or contaminated
- Condensate pipe blocked
- Flue blocked
- Spark generator fault
Plus 3 more in the answer.
- Check the gas pressure at the boiler inlet (minimum 18 mbar)
- Inspect the detection electrode for continuity, condition and position
- Check the condensate pipe and flue for blockage
- Measure 215 V DC at the gas valve while the flame is on
| Test | You should see |
|---|---|
| Gas valve unplugged, between the outside pins | 4 kΩ (±2) |
| Gas valve supply, flame on | 215 V DC |
| Gas pressure at the inlet | Above 18 mbar |
A meter reading over 150 V counts as correct, because the supply is rectified.
- Put right a low gas supply first
- Replace the detection electrode, spark generator or gas valve if proven faulty
- Check the wiring from the gas valve to the PCB, and replace the PCB only if the wiring is OK
Fault entry, page 49. Gas valve tests, page 51.
Isolate gas and power before you open the case. RGI registered engineers only for gas work.