Vaillant VU 446/5-5 / VU 606/5-5 fault F.23

Safety shutdown: temperature spread too great

Gas boiler

What it means

Safety shutdown due to excessive temperature spread between flow and return.

Likely causes

  1. Pump blocked
  2. Pump runs with insufficient output
  3. Flow and return NTC connected the wrong way round
  4. Defective pump

Where to start

  1. Check that the pump is working correctly.
  2. Check the connection for the flow and return NTC.
  3. Pull out the plug (5) for the pump