Vaillant VU 446/5-5 / VU 606/5-5 fault F.33

Air pressure switch fault

Gas boiler

What it means

A fault has been detected with the air pressure switch, often linked to flue blockage or excessive counter-pressure.

Likely causes

  1. Air/flue pipe blocked
  2. Defective air pressure switch
  3. Cable connections not plugged in/loose
  4. Fan defective
  5. PCB defective
  6. Excessive counter-pressure in the air/flue pipe

Where to start

  1. Check the entire air/flue pipe.
  2. Check the cable connections.
  3. Check that the fan works correctly.

The full answer, free

  • 2 more checks in order
  • How to put it right, step by step
  • The manual page for this fault (page 62), right under the answer

Safety: Isolate gas and power before you open the case. If you have been into the gas side, do a tightness test, and a combustion and flue check before you hand back. Gas Safe (UK) or RGI (Ireland) work only.

From the Vaillant manual for the VU 446/5-5 / VU 606/5-5. Check the model on the data plate before you order parts.